    Disconnect Switch 250A

    Original
    price: Negotiable
    minimum:
    Total supply:
    Delivery term: The date of payment from buyers deliver within days
    seat: Zhejiang
    Validity to: Long-term effective
    Last update: 2019-04-22 19:12
    Browse the number: 269
    inquiry
    Company Profile
     
     
    Product details

    中超足球赛程表 www.trezq.com HGL-100/3 disconnect switch size Suitable for AC 50HZ, rated voltage 400V/690V, rated current 63A, 80A, 100A, It acts as an isolation in the low voltage circuit. It is made of flame retardant V0 grade PA66, Contact is copper T3.


    High Electrical & Mechanical Endurance

    3-poles

    Rated thermal currents from 63A, 80A, 100A

    Designed according to IEC/ EN 60974-3


    Conventional current 100A
    Rated current In(A) 63 80 100
    Rated insulation voltage Ui (V)


    Dielectric strength (V)


    Rated surge-resistant voltage Uimp KV


    Rated working current
    AC-21B 63 80 100
    380V AC-22B 63 80 100

    AC-23B 63 80 100

    AC-21B 63 80 100
    660V AC-22B 63 80 100

    AC-23B 63 80 100
    Rated short-time withstand current lcw (kA Rms) 0.1s/1s 8 8 8
    Rated breaking capability Icn (A Rms) AC23 380 V 1000 1000 1000
    Rated making capability Icm (A Rms)AC23 380V 1250 1250 1250
    Rated shortcurrent making capabilityIcm (kA peak value) 13.6 13.6 13.6
    Mechanical durability 380V 1400 1400 1400
    Electical curability 380V 200 200 200


    HGL-100 disconnector switch size, that is, when the position is divided, there is an insulation distance and an obvious disconnection mark between the contacts in accordance with the specified requirements; in the combined position, it can carry the current under the normal loop condition and the abnormal condition within the specified time ( Switching devices for currents such as short circuits.

    The HGL disconnect switch is an important component in the low voltage circuit to ensure the safety of the operator.

    Expanded disconnect switch ampacity ratings provide the greatest amount of system configuration sizing choices commercially available in a single enclosure size.

    Loadbreak Disconnect Switch Ratings: 200A, 225A, 250A, 275A, 300A, 325A, 350A, 375A, 400A

    Optional switched negative configuration enables complete isolation of combiner box from back-fed sources.

    Provides safer and more accurate commissioning/O&M testing and inspections.


    //www.grlbusbar.com/

    Total0bar [View All]  Related Comments
     
    more»Other products

    [ Products search ] [ favorites ] [ Tell friends ] [ Print ] [ Close ]

    ?
  • 端午三件套了解一下!这些小知识让你端午更健康 2019-06-12
  • 繁峙大力发展生态农业建设绿色家园 2019-06-07
  • 内政部长威胁“单飞”,联盟党闹分裂,默克尔或下台? 2019-05-26
  • 社长手记心无旁骛40年,谭旭光是致敬改革开放的绝佳样本 2019-05-26
  • 【理上网来辉煌十九大】龚克:认识新时代 创造新辉煌 2019-05-23
  • 中方有力回击!美国多个行业喊痛:“加征关税就是对美国消费者征税” 2019-05-23
  • 暖闻丨山东小伙瞒着家人捐献造血干细胞 2019-05-21
  • 张一山恋情遭曝光,女友竟是她… 2019-05-21
  • 回复@“老笑头”,你的牛二逻辑确实很通透!论坛奇葩!哈哈哈哈! 2019-05-14
  • 不只广东有爱情故事,新疆也有,还刷爆抖音! 2019-05-12
  • 对外投资连续7个月增长(市场观察) 2019-05-12
  • 要闻 —频道 春城壹网 七彩云南 一网天下 2019-05-10
  • 安倍托人带的话都带到了,金正恩会见他吗? 2019-05-09
  • 那块“没用”的上海牌手表 2019-05-09
  • 阳泉首次颁布地方实体性法规 两部法规将于7月1日起实施 2019-05-01